Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Artigo em Inglês | Coleciona SUS | ID: biblio-945145

RESUMO

The Family Health Strategy (FHS) together with the implementation of the More Doctors Program (MDP) has an effective contribution to the strengthening of Primary Health Care (PHC) and the consolidation of the Unified Health System (SUS), which has intended to meet the health needs of the population in need of care less complex. Thus, this study aims to analyze the Family Health Strategy and the Program More Doctors implanted in the Rural Municipality of Porto Velho, Rondônia, from the perspective of nurses. This is a qualitative research, descriptive exploratory performed in the field, based on the assessment the perspective of nurses working in the FHS, which are favored by the MDP. The data collection was carried out through a questionnaire,Primary Care Assessment Tool (PCA Tool ), in its version validated in Brazil entitled PCA Tool - Brazil (BRAZIL, 2010). This instrument is widely used by national research that evaluates the quality of primary care. For the construction of the database was used Microsoft Word software. For qualitative data, the collection was carried out through interviews recorded by a script containing open questions. The response were discussed based on the content analysis technique proposed by Bardin (2011). The results achieved indicate that the MDM enabled the structuring of teams that were incomplete in the rural area of the town, however presents numerous challenges in the organization of the work process and the understanding of program objectives.


Assuntos
Estratégias de Saúde Nacionais , Programas Nacionais de Saúde , Atenção Primária à Saúde , Brasil , Enfermeiros
2.
Braz Oral Res ; 292015.
Artigo em Inglês | MEDLINE | ID: mdl-25715037

RESUMO

The instruments and materials used in health establishments are frequently exposed to microorganism contamination, and chemical products are used before sterilization to reduce occupational infection. We evaluated the antimicrobial effectiveness, physical stability, and corrosiveness of two commercial formulations of peracetic acid on experimentally contaminated specimens. Stainless steel specimens were contaminated with Staphylococcus aureus, Escherichia coli, Candida albicans, blood, and saliva and then immersed in a ready peracetic acid solution: 2% Sekusept Aktiv (SA) or 0.25% Proxitane Alpha (PA), for different times. Then, washes of these instruments were plated in culture medium and colony-forming units counted. This procedure was repeated six times per day over 24 non-consecutive days. The corrosion capacity was assessed with the mass loss test, and the concentration of peracetic acid and pH of the solutions were measured with indicator tapes. Both SA and PA significantly eliminated microorganisms; however, the SA solution was stable for only 4 days, whereas PA remained stable throughout the experiment. The concentration of peracetic acid in the SA solutions decreased over time until the chemical was undetectable, although the pH remained at 5. The PA solution had a concentration of 500-400 mg/L and a pH of 2-3. Neither formulation induced corrosion and both reduced the number of microorganisms (p = 0.0001). However, the differences observed in the performance of each product highlight the necessity of establishing a protocol for optimizing the use of each one.


Assuntos
Desinfetantes/farmacologia , Desinfecção/métodos , Ácido Peracético/farmacologia , Aço Inoxidável/química , Candida albicans/efeitos dos fármacos , Contagem de Colônia Microbiana , Corrosão , Desinfetantes/química , Estabilidade de Medicamentos , Equipamentos e Provisões/microbiologia , Escherichia coli/efeitos dos fármacos , Humanos , Ácido Peracético/química , Reprodutibilidade dos Testes , Saliva/microbiologia , Staphylococcus aureus/efeitos dos fármacos , Estatísticas não Paramétricas , Fatores de Tempo
3.
Braz. oral res. (Online) ; 29(1): 1-6, 2015. tab
Artigo em Inglês | LILACS | ID: lil-777251

RESUMO

The instruments and materials used in health establishments are frequently exposed to microorganism contamination, and chemical products are used before sterilization to reduce occupational infection. We evaluated the antimicrobial effectiveness, physical stability, and corrosiveness of two commercial formulations of peracetic acid on experimentally contaminated specimens. Stainless steel specimens were contaminated with Staphylococcus aureus, Escherichia coli, Candida albicans, blood, and saliva and then immersed in a ready peracetic acid solution: 2% Sekusept Aktiv (SA) or 0.25% Proxitane Alpha (PA), for different times. Then, washes of these instruments were plated in culture medium and colony-forming units counted. This procedure was repeated six times per day over 24 non-consecutive days. The corrosion capacity was assessed with the mass loss test, and the concentration of peracetic acid and pH of the solutions were measured with indicator tapes. Both SA and PA significantly eliminated microorganisms; however, the SA solution was stable for only 4 days, whereas PA remained stable throughout the experiment. The concentration of peracetic acid in the SA solutions decreased over time until the chemical was undetectable, although the pH remained at 5. The PA solution had a concentration of 500-400 mg/L and a pH of 2-3. Neither formulation induced corrosion and both reduced the number of microorganisms (p = 0.0001). However, the differences observed in the performance of each product highlight the necessity of establishing a protocol for optimizing the use of each one.


Assuntos
Humanos , Desinfetantes/farmacologia , Desinfecção/métodos , Ácido Peracético/farmacologia , Aço Inoxidável/química , Contagem de Colônia Microbiana , Corrosão , Candida albicans/efeitos dos fármacos , Estabilidade de Medicamentos , Desinfetantes/química , Equipamentos e Provisões/microbiologia , Escherichia coli/efeitos dos fármacos , Ácido Peracético/química , Reprodutibilidade dos Testes , Estatísticas não Paramétricas , Saliva/microbiologia , Staphylococcus aureus/efeitos dos fármacos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...